Jiangsu Yawei Transformer Co., Ltd.

1500 kva Pad Mounted Transformer

Power Rating: 1500 kVA, 1.5 MVA

Primary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 , 24.94, 4.16 or others

Secondary Voltage Ratings: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v or others

H.V. TAP RANGE: ±2×2.5% or others

Connection: Dyn11/YNyn0 or others

Type: Loop feed/Radial feed

BIL: 30-150 kV

Standards: IEEE/ANSI, CAN/CSA, DOE

 

Product Introduction

 

A 1500 kVA pad-mounted transformer is a high-capacity, robust electrical device designed for effective power distribution, particularly in large-scale commercial, industrial, or residential settings. With a 1500 kilovolt-amperes (kVA) rating, this transformer is equipped to handle substantial electrical loads, suitable for areas with high power demands.

Applications: Ideal for scenarios where space is limited or aesthetics are a concern, pad-mounted transformers are often used in suburban areas, business districts, and industrial parks. They are particularly suitable for underground electrical distribution systems.

 

Technical Parameter

 

 

Item

Unit

Parameter

High Voltage Unit

Rated frequency

Hz

50/60

Rated Voltage

kV

11

13.8,15

20,22

30,33,36

Max service voltage

kV

12

17.5

24

40.5

Rated current

A

400,630,1250,1600,2000,
2500

transformer current

A

400~2500

 

1min power frequency withstand voltage to earth and phase
to phase /Fracture

kV

42/48

48/55

55/65

85/95

BIL: to earth and phase to phase
/Fracture

kV

75/85

90/105

125/150

170/185

Rated short circuit breaking current

kA

25,31.5,40

Transformer Unit

Rated Voltage

kV

11,13.8,15,20,22,30,33,36

Rated Capacity

kVA

160~1250

Tap ranging

%

+/-2x2.5%,+/-5%

Vector Group

 

Yyn0,Dyn11

Impedance

%

4,4.5,6,8

Low Voltage Unit

Rated Voltage

V

220,400,690,800

Main circuit rated current

A

400~2500

Branch current

A

63~1250

Enclosure

Protection Level

 

HV Room:IP44
Transformer Room:IP44
LV Room:IP44

Noise level

dB

≤50

 

Product details

 

page-700-400

Main products

 

page-800-873
page-800-873
page-800-873

 

Quality Standards Of Product

 

product-1000-700

1.Quality management system GB/T 19001-2016 ISO 9001: 2015

The operation of the whole YAWEI system is strictly controlled and managed. This ensures the quality of products and material in all stages, from receiving customer requests to design, materials, production, installation, testing, packaging, delivery, after-sales, all of which operate under strict and logically linked processes.

2.CERTIFICATEOFCOMPLIANCE of UL and CUL

YaWei pad mounted transformer have been evaluated by UL in accordance with the U.S and Canada Standard(s). Our transformer certified by UL based on Canadian standards (CSA standards) .

3.Accreditation certificate CE

Standard: EN 60076-1:2011.EN 60076-2:2011EN 60076-14:2013 confirms that YAWEI technical quality meets the requirements of all specific international standards for testing and calibration laboratories. All YAWEI products are fully tested in a qualified testing room before leaving the factory, ensuring stable quality and providing absolute peace of mind for customers.

 

Rated Capacity(kVA)

No-load Loss(kW)

Load Loss(kW)

No-load Current(%)

Impendance Voltage(%)

Dimension (LxWxH)

(mm)

Total Weight

(kg)

100

200

1500

0.65

4.0

1180x1355x1735

729

150

280

2200

0.60

 

1830x1375x1735

989

200

340

2600

0.50

 

1830x1375x1735

1195

250

400

3050

0.50

 

1830x1405x1735

1355

315

480

3650

0.45

 

1830x1425x1735

1415

400

570

4300

0.45

 

1830x1435x1805

1675

500

680

5150

0.40

 

1830x1445x1860

1905

630

810

6200

0.40

4.5

1830x1445x1860

2165

800

980

7500

0.35

 

1830x1490x1860

2755

1000

1150

10300

0.35

 

1830x1675x2005

3235

1250

1360

12000

0.30

 

2100x1845x2035

4905

1600

1640

14500

0.30

 

2100x1885x2135

5835

 

Main Products Of YAWEI