Power Rating: 2500 kVA, 2.5 MVA
Primary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 or others
Secondary Voltage Ratings: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v or others
H.V. Tap Range: ±2×2.5% or others
Connection: Dyn11/YNyn0 or others
Type: Loop feed/Radial feed
BIL: 30/150 kV
Standards: IEEE, CSA, DOE

Service Conditions
1.Ambient air temperature: -30℃~+50℃
2.Altitude : Maximum installation altitude: 2500m
3.Outdoor wind speed is not more than 34m/s;
4.Relative humidity: daily average value ≤95%, the monthly average value ≤ 90%;
5.Inclination of installation site : not more than 3 °;
6.Installation site: no explosion danger, serious pollution, chemical corrosion , severe vibration
Product parameter list
|
Rated Capacity(kVA) |
No-load Loss(kW) |
Load Loss(kW) |
No-load Current(%) |
Impendance Voltage(%) |
Dimension (LxWxH) (mm) |
Total Weight (kg) |
|
100 |
200 |
1500 |
0.65 |
4.0 |
1180x1355x1735 |
729 |
|
150 |
280 |
2200 |
0.60 |
1830x1375x1735 |
989 |
|
|
200 |
340 |
2600 |
0.50 |
1830x1375x1735 |
1195 |
|
|
250 |
400 |
3050 |
0.50 |
1830x1405x1735 |
1355 |
|
|
315 |
480 |
3650 |
0.45 |
1830x1425x1735 |
1415 |
|
|
400 |
570 |
4300 |
0.45 |
1830x1435x1805 |
1675 |
|
|
500 |
680 |
5150 |
0.40 |
1830x1445x1860 |
1905 |
|
|
630 |
810 |
6200 |
0.40 |
4.5 |
1830x1445x1860 |
2165 |
|
800 |
980 |
7500 |
0.35 |
1830x1490x1860 |
2755 |
|
|
1000 |
1150 |
10300 |
0.35 |
1830x1675x2005 |
3235 |
|
|
1250 |
1360 |
12000 |
0.30 |
2100x1845x2035 |
4905 |
|
|
1600 |
1640 |
14500 |
0.30 |
2100x1885x2135 |
5835 |


Quality Standards Of Product

1.Quality management system GB/T 19001-2016 ISO 9001: 2015
The operation of the whole YAWEI system is strictly controlled and managed. This ensures the quality of products and material in all stages, from receiving customer requests to design, materials, production, installation, testing, packaging, delivery, after-sales, all of which operate under strict and logically linked processes.
2.CERTIFICATEOFCOMPLIANCE of UL and CUL
YaWei pad mounted transformer have been evaluated by UL in accordance with the U.S and Canada Standard(s). Our transformer certified by UL based on Canadian standards (CSA standards) .
3.Accreditation certificate CE
Standard: EN 60076-1:2011.EN 60076-2:2011EN 60076-14:2013 confirms that YAWEI technical quality meets the requirements of all specific international standards for testing and calibration laboratories. All YAWEI products are fully tested in a qualified testing room before leaving the factory, ensuring stable quality and providing absolute peace of mind for customers.
|
Rated Capacity(kVA) |
No-load Loss(kW) |
Load Loss(kW) |
No-load Current(%) |
Impendance Voltage(%) |
Dimension (LxWxH) (mm) |
Total Weight (kg) |
|
100 |
200 |
1500 |
0.65 |
4.0 |
1180x1355x1735 |
729 |
|
150 |
280 |
2200 |
0.60 |
1830x1375x1735 |
989 |
|
|
200 |
340 |
2600 |
0.50 |
1830x1375x1735 |
1195 |
|
|
250 |
400 |
3050 |
0.50 |
1830x1405x1735 |
1355 |
|
|
315 |
480 |
3650 |
0.45 |
1830x1425x1735 |
1415 |
|
|
400 |
570 |
4300 |
0.45 |
1830x1435x1805 |
1675 |
|
|
500 |
680 |
5150 |
0.40 |
1830x1445x1860 |
1905 |
|
|
630 |
810 |
6200 |
0.40 |
4.5 |
1830x1445x1860 |
2165 |
|
800 |
980 |
7500 |
0.35 |
1830x1490x1860 |
2755 |
|
|
1000 |
1150 |
10300 |
0.35 |
1830x1675x2005 |
3235 |
|
|
1250 |
1360 |
12000 |
0.30 |
2100x1845x2035 |
4905 |
|
|
1600 |
1640 |
14500 |
0.30 |
2100x1885x2135 |
5835 |
Main Products Of YAWEI