With the development of the economy and society, a large number of nonlinear loads have been introduced into the power grid, which has brought a series of power quality issues, such as voltage fluctuations, low power factor on the grid side, unbalanced three-phase voltage, and high harmonic content. As a result, Static Var Generators (SVG) have been introduced both domestically and internationally to address these power quality issues.
SVG Oil Immersed Distribution Transformer
SVG oil-immersed transformers are critical equipment in the power system, particularly in wind and solar photovoltaic power generation systems. They convert grid voltage to a level suitable for the operation of SVG reactive power compensation devices, achieving electrical isolation between high and low voltages and enhancing the system's reliability and stability. These transformers have high impedance and short-circuit resistance, along with optimized harmonic characteristics that help reduce voltage fluctuations and improve power quality.

SVG oil-immersed transformers serve critical functions in electrical power systems, including
1. Reactive Power Compensation: They dynamically adjust reactive power to enhance power factor and overall grid performance.
2. Integration in Renewable Energy Systems: They are used in wind and solar power systems to transform voltage levels and ensure stable operation alongside SVG devices.
3. Stability and Reliability Improvement: By supplying reactive power, they support the grid during extreme conditions, minimizing the risk of outages.
4. Harmonic Mitigation: They help control harmonic distortion caused by nonlinear loads, improving power quality.
5. Electrical Isolation: They provide isolation to prevent noise and interference, safeguarding sensitive equipment.
6. Voltage Regulation: They help maintain stable voltage levels across different loads and conditions.
These transformers are essential for maintaining the efficiency, stability, and quality of power systems, offering a range of benefits from reactive power support to harmonic suppression and electrical isolation.
Oil Filled Electrical Transformer
|
Main Technical Parameters for oil-immersed power transformer |
||||||||
|
Rated Power(kva) |
High Voltage(kv) |
H.V.Tap range |
Low Voltage(kv) |
Connection symbol |
Short Circuit Impendence |
No-load loss(kw) |
On-load loss(kw) |
No-load current(%) |
|
6300 |
63 |
±8x |
6.3 |
YNd11 |
10-14 |
9.4 |
34 |
0.63 |
|
8000 |
11.2 |
40.4 |
0.63 |
|||||
|
10000 |
13.1 |
47.6 |
0.75 |
|||||
|
12500 |
15.4 |
56.5 |
0.53 |
|||||
|
16000 |
18.5 |
69.5 |
0.49 |
|||||
|
20000 |
21.8 |
84.2 |
0.49 |
|||||
|
25000 |
25.6 |
99.5 |
0.4 |
|||||
|
31500 |
30.4 |
120 |
0.4 |
|||||
|
40000 |
36.2 |
140.3 |
0.39 |
|||||
|
50000 |
42.6 |
174.3 |
0.39 |
|||||
|
63000 |
52 |
210 |
0.39 |
|||||
|
75000 |
60 |
238 |
0.49 |
|||||
|
90000 |
69 |
274 |
0.49 |
|||||
|
120000 |
85 |
328 |
0.46 |
|||||
|
150000 |
101 |
385 |
0.42 |
|||||
|
160000 |
105 |
404 |
0.42 |
|||||
|
180000 |
115 |
436 |
0.42 |
|||||
|
240000 |
144 |
539 |
0.4 |
|||||
Quality Standards Of Product

1.Quality management system GB/T 19001-2016 ISO 9001: 2015
The operation of the whole YAWEI system is strictly controlled and managed. This ensures the quality of products and material in all stages, from receiving customer requests to design, materials, production, installation, testing, packaging, delivery, after-sales, all of which operate under strict and logically linked processes.
2.CERTIFICATEOFCOMPLIANCE of UL and CUL
YaWei pad mounted transformer have been evaluated by UL in accordance with the U.S and Canada Standard(s). Our transformer certified by UL based on Canadian standards (CSA standards) .
3.Accreditation certificate CE
Standard: EN 60076-1:2011.EN 60076-2:2011EN 60076-14:2013 confirms that YAWEI technical quality meets the requirements of all specific international standards for testing and calibration laboratories. All YAWEI products are fully tested in a qualified testing room before leaving the factory, ensuring stable quality and providing absolute peace of mind for customers.
|
Type |
(kVA) |
( LxWxH) |
(kg) |
|
S11-1000/35 |
1000 |
2600x2500x2200 |
4500 |
|
S11-2000135 |
2000 |
2800x2650x2400 |
6500 |
|
S11-3000/35 |
3000 |
3000x2800x2650 |
8500 |
|
S11-4000/35 |
4000 |
3100x2900x2950 |
10000 |
|
S11-5000/35 |
5000 |
3200x3000x3050 |
11500 |
|
S11-6000/35 |
6000 |
3260x3080x3120 |
12500 |
|
S11-7000/35 |
7•00 |
3340x3120x3180 |
14300 |
|
S11-8000/35 |
8000 |
3460x3200x3250 |
16000 |
|
S11-9000/35 |
9000 |
3530x3260x3350 |
17500 |
|
S11-10000/35 |
10000 |
3600x3350x3430 |
18600 |
|
S11-11000/35 |
11000 |
3670x3460x3510 |
20000 |
|
S11-12000/35 |
12000 |
3720x3580x3630 |
21500 |
|
S11-13000/35 |
13000 |
3760x3670x3760 |
22600 |
|
S11-14000/35 |
14000 |
3830x3750x3830 |
23400 |
|
S11-15000/35 |
1500() |
3860x3850x3910 |
25000 |
|
S11-16000/35 |
16000 |
3900x3960x4000 |
26500 |
|
S11-17000/35 |
17000 |
3950x4030x4130 |
27800 |
|
S11-18000/35 |
16000 |
4000x4100x4200 |
29500 |
|
S11-19000/35 |
1901)0 |
4070x4130x4250 |
30600 |
|
S11-20000/35 |
20000 |
4150x4200x4310 |
32000 |
Main Products Of YAWEI